SAASMENT

News

CISA lists exploited flaws in Mitel, Juniper, Xen Orchestra, and Danfoss gear.

CISA added 10 flaws to its Known Exploited Vulnerabilities catalog, covering Mitel MiCollab, Vates Xen Orchestra, Juniper Session Smart devices, and Danfoss refrigeration controllers. A separate Danfoss bug still has no patch.

Illustration of a charcoal phone, router, and console with lime patches, beside a charcoal refrigeration controller with a pink crack

Impact

What was impacted
Five flaws in the Audio, Web and Video Conferencing component of Mitel MiCollab 10.3 and earlier; an authentication bypass in Vates Xen Orchestra, CVE-2026-133469; command injection in Juniper Session Smart Conductor and Session Smart Router, CVE-2026-103406; and three flaws in Danfoss AK-SM 800A controllers. A separate unpatched bug, CVE-2026-129713, affects Danfoss AK-SM 8xxA version 5.4.0 and earlier.
Who was impacted
Operators of those products. US federal civilian agencies are told to fix eight of the ten catalog entries by November 28, 2026. CVE-2026-133311 and CVE-2025-41450 are due December 9, 2026. This report does not put the unpatched Danfoss bug on those deadlines.
What you need to do
For MiCollab, upgrade to release 10.3 and apply patch 10.3.0.18, or move to a later release. If you cannot, block external access to the conferencing component. This article names no fixed build for Xen Orchestra or for the three older Danfoss bugs, and it does not name the Juniper build. For Danfoss AK-SM 8xxA on 5.4.0 or earlier, keep remote access on a VPN or another protected network, turn on Strict mode, and wait for the 5.5.x fix.

On Wednesday, CISA added 10 security flaws to its Known Exploited Vulnerabilities catalog. Five of them are in the Audio, Web and Video Conferencing component of Mitel MiCollab and were disclosed last week. CVE-2026-133275, scored 5.3, lets an attacker upload arbitrary files. CVE-2026-133303, scored 9.0, is XML injection that can run commands in the context of the system. CVE-2026-133311, scored 5.9, can expose sensitive information through unauthorized access. CVE-2026-133323, scored 10.0, is command injection that can run commands in the context of the system. CVE-2026-133324, scored 5.3, can bypass authentication and take unauthorized actions in the application. The flaws affect MiCollab 10.3 and earlier. In an advisory dated November 16, 2026, Mitel said a patch for release 10.3 is available as 10.3.0.18. Upgrade to that release and apply the patch, or upgrade to a later release. If you cannot update, restrict external access to the conferencing component. This report does not say how the five flaws are being used.

Two more catalog entries have no fixed build named in this article. CVE-2026-133469, scored 9.8, is in Vates Xen Orchestra and is also tracked as VSA-2026-062. Someone with no account can bypass authentication and act as an administrator by presenting a crafted authentication token that contains an empty JSON object. Vates said a threat actor exploited it from the address 91.211.251[.]112 on port 8001 and from a Tor onion service on port 3333. Do not contact either address. CVE-2026-103406, scored 9.8, is command injection in Hewlett Packard Enterprise Juniper Session Smart Conductor and Session Smart Router. A remote attacker can run commands as root with a crafted Salt minion identifier. Juniper said at least one malicious use was reported to its security response team, and told customers to upgrade to a fixed release and to mitigate in the meantime. This article does not name that release or those interim steps.

The other three catalog entries are in Danfoss AK-SM 800A Series refrigeration controllers. CVE-2023-25914, scored 8.8, is path traversal that can read underlying server files through the XML interface. CVE-2023-25915, scored 9.9, is weak input checking that can let a remote attacker run commands. CVE-2025-41450, scored 8.5, is an authentication weakness that can generate a web report containing internal IP addresses, usernames, and store names. This article names no patched build for those three. Danfoss has not said they are being exploited. The report says they were likely used in high-impact attacks on supermarket chains in Europe in recent weeks, and that France attributed the October 2026 attacks on its retail sites to Shahid Kaveh, also known as Cyber Aveng3rs and Cyber Isnaad Front, an Iranian unit affiliated with the Islamic Revolutionary Guard Corps. That attribution is not the same as Danfoss confirming these bugs were used. Federal civilian agencies are told to apply fixes for all ten flaws except CVE-2026-133311 and CVE-2025-41450 by November 28, 2026. Those two are due December 9, 2026.

CISA also warned of a separate, still-unpatched flaw in Danfoss AK-SM 8xxA controllers, CVE-2026-129713, scored 9.8 and 9.3. It is a stack buffer overflow in a CGI handler that does not require a login. CISA said a crafted HTTP or HTTPS POST can corrupt memory, restart the web server, and could in theory run code with the web server's privileges. Danfoss said versions 5.4.0 and earlier are affected, that a fix is expected in 5.5.x, and that it will remove the option for customers to turn Strict mode off. Until that version exists, allow remote access only through a secure VPN or another protected network, set the units to Strict mode, and use strong passwords. CISA also says to reduce how exposed these devices are, put control-system networks and remote devices behind firewalls, and keep them off the business network. It notes that a VPN can have its own flaws, should be kept current, and is only as safe as the devices connected to it.

For your AI agent

Agent instructions — copy paste to Claude

You are helping me respond to 10 flaws CISA added to the Known Exploited Vulnerabilities catalog, plus a separate unpatched Danfoss bug. The products are Mitel MiCollab, Vates Xen Orchestra, Juniper Session Smart Conductor and Session Smart Router, and Danfoss AK-SM refrigeration controllers. Do not upload a file to MiCollab, send XML, craft an authentication token, send a Salt minion identifier, or send an HTTP POST to a controller to test any of this. Do not contact 91.211.251[.]112 or the Tor onion service named in the report. Do not write or run a proof of concept. Ask before patching a phone system, a router, or a refrigeration controller, and before changing firewall or VPN rules.

Facts from the report:
- On Wednesday, CISA added 10 flaws to the catalog. Five are in the Audio, Web and Video Conferencing component of Mitel MiCollab, disclosed last week. They affect MiCollab 10.3 and earlier. This report does not describe how they are being exploited.
- CVE-2026-133275, scored 5.3, is arbitrary file upload. CVE-2026-133303, scored 9.0, is XML injection that can run commands in the context of the system. CVE-2026-133311, scored 5.9, is unauthorized access that can obtain sensitive information. CVE-2026-133323, scored 10.0, is command injection that can run commands in the context of the system. CVE-2026-133324, scored 5.3, is an authentication bypass that can perform unauthorized actions in the application.
- Mitel's advisory, published November 16, 2026, says a patch is available for release 10.3 as 10.3.0.18. Upgrade to that release and apply the patch, or upgrade to a later release. If the update cannot be applied, restrict external access to the conferencing component.
- CVE-2026-133469, scored 9.8, is in Vates Xen Orchestra, also tracked as VSA-2026-062. An unauthenticated attacker can bypass authentication and act with administrative privileges using a crafted authentication token that contains an empty JSON object. Vates said exploitation came from 91.211.251[.]112 port 8001 and from the onion host ustar3rqxgnskzgnwkgpofgtvxevm6cx3lxdbwt4mndtveqyaohid[.]onion port 3333. This article names no fixed Xen Orchestra build. Do not invent one. Do not connect to those addresses.
- CVE-2026-103406, scored 9.8, is operating-system command injection in HPE Juniper Session Smart Conductor and Session Smart Router. A remote attacker can run commands as root via a crafted Salt minion identifier. Juniper said at least one malicious exploitation was reported to its SIRT, and told customers to upgrade to a fixed release and mitigate in the meantime. This article does not name the fixed release or the mitigation steps. Do not guess a version number.
- Danfoss AK-SM 800A Series: CVE-2023-25914, scored 8.8, path traversal that can read server files via the XML interface; CVE-2023-25915, scored 9.9, improper input validation that can let a remote attacker run commands; CVE-2025-41450, scored 8.5, improper authentication that can generate a web report with internal IP addresses, usernames, and store names. This article names no patched build. Danfoss has not said these three are exploited. The report says they were likely used against supermarket chains in Europe in recent weeks. France attributed October 2026 attacks on its retail sites to Shahid Kaveh, also called Cyber Aveng3rs and Cyber Isnaad Front, an IRGC-affiliated unit. Do not state that Danfoss or France confirmed these CVE IDs in those attacks.
- Federal civilian agencies are advised to fix all ten flaws except CVE-2026-133311 and CVE-2025-41450 by November 28, 2026. Those two are due December 9, 2026.
- Separately, CVE-2026-129713, scored 9.8 and 9.3, is an unpatched stack-based buffer overflow in an unauthenticated CGI handler on Danfoss AK-SM 8xxA Series controllers. CISA said a crafted HTTP or HTTPS POST can cause memory corruption, a web server restart, and hypothetically code execution with web server privileges. No authentication is required. Danfoss said versions 5.4.0 and earlier are affected and that a fix is expected in 5.5.x. Danfoss will remove the option that lets customers disable Strict mode. This report does not assign the November 28 or December 9 dates to this CVE.
- Until 5.5.x exists, Danfoss advises remote access only through a secure VPN or another protected network, Strict mode, and strong passwords. CISA advises minimizing network exposure, placing control-system networks and remote devices behind firewalls, and isolating them from business networks. It also says a VPN may have vulnerabilities, should be updated, and is only as secure as the devices connected to it.

Context:
- What was impacted: MiCollab conferencing, Xen Orchestra, Juniper Session Smart devices, and Danfoss AK-SM 800A and 8xxA controllers.
- Who should care: anyone running those products, and federal civilian agencies with the catalog deadlines above.
- What to do: apply the Mitel patch this report names, get the unnamed Juniper and Xen Orchestra fixes from the vendors without guessing versions, and isolate unpatched Danfoss controllers.

Do this in order. Ask before changing a device, a firewall rule, or a password. Prefer read-only inventory first. Do not write or run an exploit or a proof of concept.

1. Inventory
   - Record whether we run Mitel MiCollab, and the version. Note whether the conferencing component is reachable from the internet. Do not upload a file to check.
   - Record whether we run Vates Xen Orchestra. Search logs for connections to 91.211.251[.]112 port 8001 or to that onion host on port 3333. Do not contact them. This report names no safe Xen Orchestra version.
   - Record whether we run Juniper Session Smart Conductor or Session Smart Router. Do not invent a target version. If a vendor advisory we already hold names a fixed release, quote that version and where it came from. If we do not hold one, say the version is not in this report.
   - Record Danfoss AK-SM model and software version. Separate 800A units from 8xxA units on 5.4.0 or earlier. Record whether Strict mode is on, and whether the controller is reachable from outside a protected network. Do not send a request to the CGI handler.
2. Contain
   - If MiCollab cannot be patched yet and I agree, propose blocking external access to the conferencing component. Do not shut down voice service in this step.
   - If an 8xxA controller on 5.4.0 or earlier is reachable from the internet, propose limiting it to a VPN or another protected network, and turning on Strict mode, only after I agree. Do not disable Strict mode.
   - Do not add a blanket block of every address in this prompt to the corporate firewall unless I ask. The Xen Orchestra addresses are hunt indicators from Vates, not a full block list for the other products.
3. Remediate
   - For MiCollab 10.3 and earlier, after I agree, upgrade to release 10.3 and apply 10.3.0.18, or upgrade to a later release. Do not stop at a 10.3 build that is older than that patch.
   - For Juniper and Xen Orchestra, do not pick a version number that this report does not contain. Show me the vendor fixed release before you install it.
   - For the three AK-SM 800A flaws, this report names no build. Do not invent one. Tell me that and stop for a vendor check.
   - For CVE-2026-129713, do not install 5.5.x until that release exists. This report says it is upcoming, not available.
4. Verify
   - If I asked you to change something, list the device, the version before and after, and the access path you changed.
   - If I did not, report the inventory only.
5. Report back
   - Which of these products we run, the versions, whether the Mitel conferencing component or a Danfoss controller is exposed, and any log hit on the Xen Orchestra addresses. State the federal dates only as catalog deadlines for the ten flaws, with CVE-2026-133311 and CVE-2025-41450 due December 9, 2026 and the other eight due November 28, 2026.

Do not invent a Juniper build, a Xen Orchestra build, a Danfoss 800A patch, or a claim that Shahid Kaveh used a named CVE. If a check needs access I have not given you, say what you need and stop.

← All news

Try the platform.

Open the demo workspace with mock data. No login. Register from the banner when you want early access. No security team. No call.