SonicWall Gen 6 firewalls will not get patches, even for critical flaws.
SonicWall told customers still running Generation 6 firewalls to retire them and take them off the internet edge. Those devices will not receive security patches, including for critical flaws.

Impact
- What was impacted
- SonicWall Generation 6 firewalls running SonicOS 6.x. SonicWall says these devices are no longer supported and will not receive security patches, even for critical flaws. It expects internet-facing Gen 6 firewalls to be actively targeted. This notice does not name a CVE.
- Who was impacted
- Anyone still running a Gen 6 SonicWall firewall, especially one exposed to the internet or used for remote access. The listed families are TZ, SOHO, NSA, NSa, SuperMassive, NSsp, and Gen 6 virtual NSv appliances.
- What you need to do
- Inventory every Gen 6 firewall. Replace internet-facing units and units that provide remote access first, with a Gen 8 firewall running SonicOS 8. Until a unit is replaced, turn off WAN management for HTTPS, SSH, and SNMP, turn off SSL VPN or limit it to known source addresses, require multi-factor authentication on remaining remote-access and admin accounts, reset local passwords, disable unused services and interfaces, and watch logs for unusual logins, configuration changes, and traffic. This notice does not offer a SonicOS 6.x patch.
SonicWall told customers still running Generation 6 firewalls to retire and replace them, and to stop placing them on the internet edge. The company says attackers now use automation and AI to find unsupported edge devices faster, and it expects internet-facing Gen 6 firewalls to be actively targeted. It says to treat any Gen 6 firewall still in service as a high-risk exposure. The replacement it names is a supported Gen 8 firewall running SonicOS 8. This notice does not name a CVE, and it does not say a SonicOS 6.x update will close the exposure.
The products it lists as running SonicOS 6.x are the TZ300, TZ300W, TZ300P, TZ350, TZ350W, TZ400, TZ400W, TZ500, TZ500W, TZ600, and TZ600P; SOHO, SOHO W, SOHO 250, and SOHO 250W; NSA 2600, NSA 3600, NSA 4600, NSA 5600, and NSA 6600; NSa 2650, NSa 3650, NSa 4650, NSa 5650, NSa 6650, NSa 9250, NSa 9450, and NSa 9650; SuperMassive 9200, 9400, 9600, and 9800; NSsp 12400 and NSsp 12800; and Gen 6 virtual appliances from NSv 10 to NSv 1600. SonicWall says Gen 6 is no longer actively supported and will not receive patches, even for critical flaws.
Until a firewall is replaced, SonicWall says to disable WAN management, meaning HTTPS, SSH, and SNMP on WAN interfaces. Disable SSL VPN, or restrict it to known source addresses. Enforce multi-factor authentication on every remaining remote-access and admin account, and reset local passwords. Disable services and interfaces that are not in use. Watch logs for unusual logins, configuration changes, and traffic. Contact an authorized SonicWall partner to plan the move to Gen 8. SonicWall says a compromised perimeter firewall can be a foothold for credential theft, lateral movement, and ransomware.
For your AI agent
Agent instructions — copy paste to Claude
You are helping me respond to SonicWall's notice that Generation 6 firewalls running SonicOS 6.x will not receive security patches, including for critical flaws. Do not write or run an exploit or a proof of concept. Do not invent a CVE, a SonicOS 6.x patch, or a Gen 7 replacement. Do not scan the public internet for these devices. Ask before changing firewall rules, resetting passwords, disabling VPN, or replacing hardware. Facts from the notice: - SonicWall told customers still running Generation 6 firewalls to retire and replace them immediately and to stop exposing them on the internet edge. - SonicWall says attackers now use automation and AI to find and exploit unsupported edge devices faster, and it expects internet-facing Gen 6 firewalls to be actively targeted. Treat any Gen 6 firewall still in service as a high-risk exposure. - The replacement it names is a supported Gen 8 firewall running SonicOS 8. Do not propose staying on SonicOS 6.x with a patch. This notice says Gen 6 will not get patches, even for critical flaws. This notice does not name a CVE. Do not invent one. - Products it lists as running SonicOS 6.x: TZ300, TZ300W, TZ300P, TZ350, TZ350W, TZ400, TZ400W, TZ500, TZ500W, TZ600, TZ600P; SOHO, SOHO W, SOHO 250, SOHO 250W; NSA 2600, NSA 3600, NSA 4600, NSA 5600, NSA 6600; NSa 2650, NSa 3650, NSa 4650, NSa 5650, NSa 6650, NSa 9250, NSa 9450, NSa 9650; SuperMassive 9200, 9400, 9600, 9800; NSsp 12400 and NSsp 12800; Gen 6 virtual appliances from NSv 10 to NSv 1600. - Until replacement: disable WAN management (HTTPS, SSH, and SNMP on WAN interfaces); disable SSL VPN or restrict it to known source addresses; enforce multi-factor authentication on every remaining remote-access and admin account and reset local passwords; disable unused services and interfaces; monitor logs for unusual logins, configuration changes, and traffic. - SonicWall says to contact an authorized SonicWall partner to plan the migration. It says a compromised perimeter firewall can be a foothold for credential theft, lateral movement, and ransomware. Do not invent a detection signature or a specific malware family for this notice. Context: - What was impacted: Generation 6 SonicWall firewalls that will not receive further security patches. - Who should care: operators of those firewalls, especially units on the internet edge or used for remote access. - What to do: inventory them, replace them with Gen 8 running SonicOS 8, and apply the interim exposure cuts until that replacement is in place. Do this in order. Ask before changing a firewall, resetting a password, disabling remote access, or buying or installing a replacement. Prefer read-only inventory first. Do not write or run an exploit or a proof of concept. 1. Inventory - List SonicWall firewalls and record the model and SonicOS version. Flag any model in the list above, and any device still on SonicOS 6.x. If a model is not in the list and the version is not 6.x, do not mark it as Gen 6. - Record which flagged units are reachable from the internet or provide remote access, including SSL VPN. - Do not invent a CVE to search for. This notice does not name one. 2. Contain - For each flagged unit that is still online, propose disabling WAN management for HTTPS, SSH, and SNMP, and disabling SSL VPN or limiting it to known source addresses. Ask before changing the configuration. - Propose multi-factor authentication on remaining remote-access and admin accounts, and a reset of local passwords. Ask before resetting passwords or locking anyone out. - Propose disabling services and interfaces that the operator confirms are unused. If you cannot tell, say so and do not disable them. 3. Remediate - Plan replacement with a Gen 8 firewall running SonicOS 8, starting with internet-facing units and units that provide remote access. Ask before ordering hardware or changing the production path. This notice says to contact an authorized SonicWall partner for the migration. Do not invent a Gen 7 or a SonicOS 6.x build as the fix. 4. Verify - Confirm which units are still Gen 6, which interim controls were applied only if you were asked to apply them, and which units have a replacement plan. - Confirm logs are being watched for unusual logins, configuration changes, and traffic only if that watch was set up. 5. Report back - The Gen 6 inventory, which units are internet-facing or used for remote access, what you changed, and what is still waiting because this notice has no patch. Do not invent CVEs, firmware builds, or model numbers. If a check needs access I have not given you, say what you need and stop.